this post was submitted on 29 Jul 2025
564 points (98.0% liked)

Ask Lemmy

33674 readers
1456 users here now

A Fediverse community for open-ended, thought provoking questions


Rules: (interactive)


1) Be nice and; have funDoxxing, trolling, sealioning, racism, and toxicity are not welcomed in AskLemmy. Remember what your mother said: if you can't say something nice, don't say anything at all. In addition, the site-wide Lemmy.world terms of service also apply here. Please familiarize yourself with them


2) All posts must end with a '?'This is sort of like Jeopardy. Please phrase all post titles in the form of a proper question ending with ?


3) No spamPlease do not flood the community with nonsense. Actual suspected spammers will be banned on site. No astroturfing.


4) NSFW is okay, within reasonJust remember to tag posts with either a content warning or a [NSFW] tag. Overtly sexual posts are not allowed, please direct them to either !asklemmyafterdark@lemmy.world or !asklemmynsfw@lemmynsfw.com. NSFW comments should be restricted to posts tagged [NSFW].


5) This is not a support community.
It is not a place for 'how do I?', type questions. If you have any questions regarding the site itself or would like to report a community, please direct them to Lemmy.world Support or email info@lemmy.world. For other questions check our partnered communities list, or use the search function.


6) No US Politics.
Please don't post about current US Politics. If you need to do this, try !politicaldiscussion@lemmy.world or !askusa@discuss.online


Reminder: The terms of service apply here too.

Partnered Communities:

Tech Support

No Stupid Questions

You Should Know

Reddit

Jokes

Ask Ouija


Logo design credit goes to: tubbadu


founded 2 years ago
MODERATORS
 

A useful source:
https://worldofsockets.com/

you are viewing a single comment's thread
view the rest of the comments
[–] slazer2au@lemmy.world 62 points 1 day ago (4 children)

Type I

Earth pin doesn't cause the plug to murder your feet like the UK plug.
Angled pins to prevent cross polarisation.
Localised power switch per socket so you can turn something on or off with your toe and not bend down to unplug it.
Looks like a ghost face and when in the double gang formation the switches when on looks like the plate is high.

collapsed inline media

[–] Stovetop@lemmy.world 33 points 1 day ago (2 children)

The main problem with type I (and a few others) is that it's not recessed. If it comes loose a bit, you still have the problem of exposed live pins.

[–] GreatAlbatross@feddit.uk 18 points 1 day ago

And the thin pins means that with any weight (wall-wart, etc.), it starts to come out.
Doubly so if it's set into thin plasterboard that already wobbles.

[–] ms_lane@lemmy.world 16 points 1 day ago

Pins are insulated since 2003.

[–] SomeoneSomewhere@lemmy.nz 8 points 1 day ago

Also:

Thin stamped construction is cheap, but can still be fitted with sleeving on the live (active and neutral) pins like UK & europlug, but not US plugs. This prevents objects or fingers getting to live pins on a partially inserted plug.

Industry has agreed that leads exit either straight out, or down-and-right, so there is no conflict for horizontal or vertical sockets. Sockets are universally installed earth-down.

Reasonably compact.

[–] Redjard@lemmy.dbzer0.com 3 points 1 day ago (2 children)

collapsed inline media
collapsed inline media

Some images of the plugs, since I didn't know what they looked like.

It was mentioned the pins started being insulated like that second image 20 years ago, but going by the images I found the older uninsulated style is still more common. This is ofc a major shock hazard when plugging in your stuff.

Even with the insulation, you can still reach under the half inserted plug, just less easily and maybe only if you have smaller hands (like children).

Fundamentally flat sockets are doomed to be shock hazards, compare it to the recessed sockets where the entire surface the contacts insert into is cut off from reach before the pin insertion starts, and on top of that the pins of say type F have been insulated for so long many don't know there were uninsulated variants.

Another bonus of the recessed style is the plug doesn't stick as far out of your walls. For extension cords it's probably a bit bulkier, but when you sink the recession into the wallbox of the outlet you can get as flush as the width of the cable with an angled plug.

collapsed inline media

Also pretty sure you can step on angled type I plugs resting on their backs. The recessed plugs usually have grips on top so can't rest on their back even when angled. Their pins are also ball-shaped on the end, type I looks quite angular and more painful.

[–] unknown@sh.itjust.works 6 points 1 day ago

I live in Australia and I just did an audit of the power board that was sitting next to my bed. All four devices and the power board itself all have the insulated pins. I can't remember the last time I saw one that didn't have insulated pins. I'm sure they exist, but they are not common.

We also have RCD on all our circuits so if someone is able to short the pins, it will trip within 20ms or less.

[–] ms_lane@lemmy.world 2 points 23 hours ago (1 children)

Ironically, those are upside down.

Which usually indicates Chinese Type I - they don't insulate pins but do put earth on top.

We insulate pins but live/neutral is on top.

[–] Redjard@lemmy.dbzer0.com 1 points 23 hours ago

Oof, I see.
Kinda a bad look for type I when some of the users follow a different spec and ruin all attempts at improving safety or even keeping standards like earth being down.

In comparison the european plugs are moving closer together, for example F+E combo plugs are increasingly common.

[–] alansuspect@aussie.zone 1 points 8 hours ago

I'm a G guy at heart but use I now. My main issue is how easily the pins can bend.