this post was submitted on 16 Jun 2025
288 points (92.9% liked)

Technology

71558 readers
3646 users here now

This is a most excellent place for technology news and articles.


Our Rules


  1. Follow the lemmy.world rules.
  2. Only tech related news or articles.
  3. Be excellent to each other!
  4. Mod approved content bots can post up to 10 articles per day.
  5. Threads asking for personal tech support may be deleted.
  6. Politics threads may be removed.
  7. No memes allowed as posts, OK to post as comments.
  8. Only approved bots from the list below, this includes using AI responses and summaries. To ask if your bot can be added please contact a mod.
  9. Check for duplicates before posting, duplicates may be removed
  10. Accounts 7 days and younger will have their posts automatically removed.

Approved Bots


founded 2 years ago
MODERATORS
you are viewing a single comment's thread
view the rest of the comments
[–] bluGill@fedia.io 8 points 1 day ago (1 children)

Running more than one outlet on a 220 circute is generally against us codes. It will work but don't do it.

I have a phev with only 30 miles of range - ofen I get home with a nearly dead battery and need to leave again soon - I want faster charging. I'm sure someone with 200 miles of range can be fine on 110 volt slow charging as there likely enough time over a week that it works.

[–] chaospatterns@lemmy.world 6 points 1 day ago* (last edited 1 day ago) (2 children)

I think #1 is suggesting to move the neutral over to another hot phase and change the outlet to a 240v nema 6/three prong (I think) with two hots and a ground instead of the 4 prong.

The 240v at the same amps gives you higher watts so faster charging without an expensive new conductor. I'm

[–] Cort@lemmy.world 7 points 1 day ago

The problem with #1 is that most garages only have one circuit for the outlets AND the garage door opener. Moving to 240v would fry the opener.

[–] IphtashuFitz@lemmy.world 2 points 1 day ago (1 children)

Changing a 120v line over to 240 is likely also against code even if the physical cable can handle it. 120V cable is typically white/black/green, and the electrical code prohibits using the white one as a hot leg. That’s why 240V cable of the same AWG is red/black/green. The red & black legs both carry 120V.

[–] bluGill@fedia.io 6 points 1 day ago (1 children)

Code allows painting the white conductor black which is what i do. Or at least it did 10 years ago when I last checked.

This.

That said, it's rare that only one or two outlets in a garage are tied to a breaker. Usually they're all on one circuit in older homes, in my experience.

If you can find a circuit like this, though, it's perfectly valid. Many chargers made for 110V also have a 230V/15 or 20 amp mode. My Mother-in-law's portable charger has a 230V NEMA 2-20 adapter that comes in the bag with it.