this post was submitted on 16 Jun 2025
291 points (92.9% liked)

Technology

71558 readers
4385 users here now

This is a most excellent place for technology news and articles.


Our Rules


  1. Follow the lemmy.world rules.
  2. Only tech related news or articles.
  3. Be excellent to each other!
  4. Mod approved content bots can post up to 10 articles per day.
  5. Threads asking for personal tech support may be deleted.
  6. Politics threads may be removed.
  7. No memes allowed as posts, OK to post as comments.
  8. Only approved bots from the list below, this includes using AI responses and summaries. To ask if your bot can be added please contact a mod.
  9. Check for duplicates before posting, duplicates may be removed
  10. Accounts 7 days and younger will have their posts automatically removed.

Approved Bots


founded 2 years ago
MODERATORS
you are viewing a single comment's thread
view the rest of the comments
[–] IphtashuFitz@lemmy.world 2 points 1 day ago (1 children)

Changing a 120v line over to 240 is likely also against code even if the physical cable can handle it. 120V cable is typically white/black/green, and the electrical code prohibits using the white one as a hot leg. That’s why 240V cable of the same AWG is red/black/green. The red & black legs both carry 120V.

[–] bluGill@fedia.io 6 points 1 day ago (1 children)

Code allows painting the white conductor black which is what i do. Or at least it did 10 years ago when I last checked.

This.

That said, it's rare that only one or two outlets in a garage are tied to a breaker. Usually they're all on one circuit in older homes, in my experience.

If you can find a circuit like this, though, it's perfectly valid. Many chargers made for 110V also have a 230V/15 or 20 amp mode. My Mother-in-law's portable charger has a 230V NEMA 2-20 adapter that comes in the bag with it.