this post was submitted on 10 May 2025
775 points (99.6% liked)

pics

22289 readers
1093 users here now

Rules:

1.. Please mark original photos with [OC] in the title if you're the photographer

2..Pictures containing a politician from any country or planet are prohibited, this is a community voted on rule.

3.. Image must be a photograph, no AI or digital art.

4.. No NSFW/Cosplay/Spam/Trolling images.

5.. Be civil. No racism or bigotry.

Photo of the Week Rule(s):

1.. On Fridays, the most upvoted original, marked [OC], photo posted between Friday and Thursday will be the next week's banner and featured photo.

2.. The weekly photos will be saved for an end of the year run off.

Weeks 2023

Instance-wide rules always apply. https://mastodon.world/about

founded 2 years ago
MODERATORS
 
all 45 comments
sorted by: hot top controversial new old
[–] TWeaK@lemm.ee 55 points 4 weeks ago (2 children)

Fun fact: You can estimate the voltage by the length of the insulators. My guess is this is around 100kV (2x 3 phase circuits), around the border of transmission and distribution voltages.

You can also estimate the capacity by the number of conductors per phase. This has a pair of lines for each phase, so a fair chunk, but not the 3 or 4 conductors you sometimes see (although maybe you mainly see that on higher transmission voltages.

[–] Jhestyr@lemmy.world 29 points 4 weeks ago (1 children)

Ooh a lightning sorcerer...

[–] InverseParallax@lemmy.world 16 points 4 weeks ago

There are some who call him: Tim?

[–] sartalon@lemmy.world 2 points 4 weeks ago* (last edited 4 weeks ago) (2 children)

It will be 128 kV or 345 kV.

[–] qupada@fedia.io 14 points 4 weeks ago (2 children)

OP appears to be in the UK, so potentially (no pun intended) one of 400kV, 275kV, or 132kV.

[–] TWeaK@lemm.ee 5 points 3 weeks ago* (last edited 3 weeks ago) (1 children)

That pun was totally intended, and I cannot fault you for it.

I was thinking 132kV, but wasn't sure if this is Europe where you might find 100kV (although again it varies by country). In the UK, 132kV is the boundary between distribution and transmission. DNO's (Distribution Network Operators) generally use 11kV, 33kV, 66kV (generally rare but used in some areas eg in North West England) and 132kV, TNO's (Transmission) use 132kV, 275kV and 400kV. Although, a lot of 275kV substations are built to 400kV spec (eg in Scotland), so that they can upgrade in the future.

You sometimes get this with power lines, they might install higher voltage insulators then run it at a lower voltage until some time later when the network is upgraded. This spoils the game of guess the voltage/makes it more challenging, and you end up with really weird looking connections between large pylons and small poles.

[–] CelloMike@lemmy.world 6 points 3 weeks ago

According to the national grid map this is a 275kv line so there you go :)

no pun intended

None taken.

[–] TWeaK@lemm.ee 4 points 3 weeks ago

The more I look at it I think it might be a 132kV line on a 400kV tower, with the intention to upgrade it some time in the future. I say this because the insulators aren't actually the full length of the spacing from the tower, there's a separator between the tower and the start of the insulator fins. This makes me think they've left room for longer 400kV insulators to be installed.

Saying that though I have no idea, there could have been all sorts of other considerations that led to a configuration like that.

[–] ThePyroPython@lemmy.world 25 points 4 weeks ago (2 children)
[–] expatriado@lemmy.world 19 points 4 weeks ago* (last edited 4 weeks ago) (2 children)

collapsed inline media

i work for a utility company, we got even simpler ones on the wall 😄

[–] altima_neo@lemmy.zip 11 points 4 weeks ago (1 children)

That's some hot centerfolds

[–] perestroika@lemm.ee 2 points 3 weeks ago* (last edited 3 weeks ago)

Wait until you happen to visit to Risti, Estonia, where a mast named Soorebane inhabits an intersection of some country roads. :)

Of course, it's an artsy decorative exception for where a high voltage line must cross through a public place. In all other places, ordinary lattice grid masts.

[–] ParadoxSeahorse@lemmy.world 3 points 4 weeks ago

The ThePyroPython Pylon

[–] Brunbrun6766@lemmy.world 19 points 4 weeks ago

Seems like something we should construct more of

[–] i_am_not_a_robot@feddit.uk 17 points 4 weeks ago (2 children)
[–] Genius@lemmy.zip 7 points 4 weeks ago (2 children)

Far over the misty pylons tall

[–] tetris11@feddit.uk 1 points 3 weeks ago* (last edited 3 weeks ago)

Two voltage deep, resistance Ohm

[–] sneezycat@sopuli.xyz 14 points 4 weeks ago (1 children)

You are now trapped by my stand『SUPER FLY』

collapsed inline media

[–] Appoxo@lemmy.dbzer0.com 12 points 4 weeks ago

I like geometric patterns :)

[–] PotatoLibre@feddit.it 12 points 4 weeks ago

I like when something usually considered just background becomes interesting.

[–] ramius345@sh.itjust.works 11 points 4 weeks ago (1 children)
[–] spittingimage@lemmy.world 6 points 4 weeks ago

Looking up an electricity pylon's skirt.

[–] Mustakrakish@lemmy.world 6 points 3 weeks ago (1 children)

If I remember correctly, you are now trapped there until you trick someone else into taking your spot.

[–] Couldbealeotard@lemmy.world 2 points 3 weeks ago

At least your knives will be sharp

[–] Pnut@lemm.ee 5 points 3 weeks ago

The effing tower.

[–] daepicgamerbro69@lemmy.world 4 points 4 weeks ago (1 children)

Did you also get to see the Mona Lisa?

[–] DonGirses@lemmy.world 1 points 3 weeks ago

No, but I saw some high school students arguing with a hobo

[–] don@lemm.ee 4 points 4 weeks ago (1 children)

Looks like part of a space station orbiting a water planet

[–] stockhausen@sopuli.xyz 3 points 4 weeks ago

Damn, now I can't unsee it!

[–] AngryCommieKender@lemmy.world 4 points 4 weeks ago

Did you get a buzzing sensation being under it?

[–] xc2215x@lemmy.world 4 points 4 weeks ago

That looks super neat.

[–] InfiniteHench@lemmy.world 3 points 4 weeks ago

Damn I’ve always wanted to stop along the highway and get a shot like this. Great pic. Thank you

[–] Rebels_Droppin@lemmy.world 3 points 4 weeks ago

This, this I like.

[–] b_tr3e@feddit.org 3 points 4 weeks ago
  • escape route?
  • thermal starter?
  • timer?
  • thermite?
  • battery?

...good luck!

[–] Shardikprime@lemmy.world 3 points 3 weeks ago

Everyone who sees anything on this picture... Are you sure you are not enemy stand users?

damn the 5g radiation coming from this photo is enlarging my gayness allele

[–] Doomsider@lemmy.world 2 points 4 weeks ago

Love this perspective shot.

[–] markstos@lemmy.world 1 points 3 weeks ago

Some of these were installed on my family farm in the US through eminent domain. Meaning, we had no choice but the government was supposed to pay us a fair market value for the use of our land. I still remember that because that year all us three kids all got new bicycles!

I don't love them. If you are right underneath them, it seems like you feel the electricity and sometimes hear them crackle.