Mildly Infuriating
Home to all things "Mildly Infuriating" Not infuriating, not enraging. Mildly Infuriating. All posts should reflect that. Please post actually infuriating posts to !actually_infuriating@lemmy.world
I want my day mildly ruined, not completely ruined. Please remember to refrain from reposting old content. If you post a post from reddit it is good practice to include a link and credit the OP. I'm not about stealing content!
It's just good to get something in this website for casual viewing whilst refreshing original content is added overtime.
Rules:
1. Be Respectful
Refrain from using harmful language pertaining to a protected characteristic: e.g. race, gender, sexuality, disability or religion.
Refrain from being argumentative when responding or commenting to posts/replies. Personal attacks are not welcome here.
...
2. No Illegal Content
Content that violates the law. Any post/comment found to be in breach of common law will be removed and given to the authorities if required.
That means: -No promoting violence/threats against any individuals
-No CSA content or Revenge Porn
-No sharing private/personal information (Doxxing)
...
3. No Spam
Posting the same post, no matter the intent is against the rules.
-If you have posted content, please refrain from re-posting said content within this community.
-Do not spam posts with intent to harass, annoy, bully, advertise, scam or harm this community.
-No posting Scams/Advertisements/Phishing Links/IP Grabbers
-No Bots, Bots will be banned from the community.
...
4. No Porn/Explicit
Content
-Do not post explicit content. Lemmy.World is not the instance for NSFW content.
-Do not post Gore or Shock Content.
...
5. No Enciting Harassment,
Brigading, Doxxing or Witch Hunts
-Do not Brigade other Communities
-No calls to action against other communities/users within Lemmy or outside of Lemmy.
-No Witch Hunts against users/communities.
-No content that harasses members within or outside of the community.
...
6. NSFW should be behind NSFW tags.
-Content that is NSFW should be behind NSFW tags.
-Content that might be distressing should be kept behind NSFW tags.
...
7. Content should match the theme of this community.
-Content should be Mildly infuriating. If your post better fits !Actually_Infuriating put it there.
-The Community !actuallyinfuriating has been born so that's where you should post the big stuff.
...
8. Reposting of Reddit content is permitted, try to credit the OC.
-Please consider crediting the OC when reposting content. A name of the user or a link to the original post is sufficient.
...
...
Also check out:
Partnered Communities:
Reach out to LillianVS for inclusion on the sidebar.
All communities included on the sidebar are to be made in compliance with the instance rules.
view the rest of the comments
I happen to have (several) 30A 240V circuits in my house and shop. The one I was using tonight has an arc welder plugged into it. Under the applicable electric code in the US, this circuit has to be dedicated. It can serve only one outlet. If I want another 30A outlet, I have to wire a completely separate, dedicated circuit for that outlet. I can only install such outlets in certain places within my home and shop.
That is the standard here in North America. The standard for EU, Japan, and the rest of the world is comparable. North America (And possibly Japan?) has an additional feature in that our 240V circuits are split-phase: They expose the user to a maximum 120V fault to ground. To experience a 240V fault, you have to be ungrounded and simultaneously contact not just one but two opposing hot phases.
The UK daisy chains single-phase, 240V to ground, 30A outlets throughout their homes. They put circuits suitable for arc welding in their bathrooms. They use circuits suitable for arc welding for their alarm clocks and hair dryers.
The UK requirements on 30A circuits and outlets are far less restrictive than the requirements on 30A circuits and outlets in the rest of the world. The UK uses substandard household circuits, necessitating their over-engineered plug.
The UK could have deprecated their 30A circuits in favor of the 16A circuits in use in Europe. They elected to keep their substandard, arc-welder-ready outlets and over-engineer a plug instead.
And here we are again. For the billionth fucking time in a row:
THE CURRENT CAPACITY OF A CIRCUIT HAS ZERO, NADA, NULL INFLUENCE ON THAT CIRCUITS ELECTRIC SHOCK POTENTIAL OR SEVERERTY AND IS NOT RELEVANT WHATSOEVER FOR HUMAN SAFETY.
And device safety is MORE THAN adequately provided by fused plugs. You just irrationally hate the UK network for some fucking reason, and are yet completely incapable of providing even a singular valid argument as to it being less safe.
Of course it is. That's not the issue under discussion. The issue under discussion is "Why does the UK use overengineered plugs not needed in the rest of the world?"
And the answer is because their household circuits are radically substandard relative to those in use in the rest of the world. Without those special plugs, UK circuits would be extraordinarily dangerous.
People die in fires.
Not the topic of discussion. Again, the topic is "Why does the UK use overengineered plugs not needed in the rest of the world?" To understand that, we consider the hypothetical use of non-fused plugs on UK circuits, compared to non-fused plugs on global circuits. When we consider that hypothetical, we realize the exceptional danger posed by that condition, and we identify the need for those plugs.
Because that is not the topic of discussion. The topic of discussion is "Why does the UK use overengineered plugs not needed in the rest of the world?" The danger is not the plugs. The danger is the household circuitry. The plugs are the safety device grafted on to restore the degree of safety the rest of the world enjoys without those special plugs. Of course the plugs are safe. The danger arises when we hypothetically apply the world's non-fused-plug standard to UK household circuits, in order to understand the necessity of those plugs.
Projection.