Mildly Infuriating
Home to all things "Mildly Infuriating" Not infuriating, not enraging. Mildly Infuriating. All posts should reflect that.
I want my day mildly ruined, not completely ruined. Please remember to refrain from reposting old content. If you post a post from reddit it is good practice to include a link and credit the OP. I'm not about stealing content!
It's just good to get something in this website for casual viewing whilst refreshing original content is added overtime.
Rules:
1. Be Respectful
Refrain from using harmful language pertaining to a protected characteristic: e.g. race, gender, sexuality, disability or religion.
Refrain from being argumentative when responding or commenting to posts/replies. Personal attacks are not welcome here.
...
2. No Illegal Content
Content that violates the law. Any post/comment found to be in breach of common law will be removed and given to the authorities if required.
That means: -No promoting violence/threats against any individuals
-No CSA content or Revenge Porn
-No sharing private/personal information (Doxxing)
...
3. No Spam
Posting the same post, no matter the intent is against the rules.
-If you have posted content, please refrain from re-posting said content within this community.
-Do not spam posts with intent to harass, annoy, bully, advertise, scam or harm this community.
-No posting Scams/Advertisements/Phishing Links/IP Grabbers
-No Bots, Bots will be banned from the community.
...
4. No Porn/Explicit
Content
-Do not post explicit content. Lemmy.World is not the instance for NSFW content.
-Do not post Gore or Shock Content.
...
5. No Enciting Harassment,
Brigading, Doxxing or Witch Hunts
-Do not Brigade other Communities
-No calls to action against other communities/users within Lemmy or outside of Lemmy.
-No Witch Hunts against users/communities.
-No content that harasses members within or outside of the community.
...
6. NSFW should be behind NSFW tags.
-Content that is NSFW should be behind NSFW tags.
-Content that might be distressing should be kept behind NSFW tags.
...
7. Content should match the theme of this community.
-Content should be Mildly infuriating.
-The Community !actuallyinfuriating has been born so that's where you should post the big stuff.
...
8. Reposting of Reddit content is permitted, try to credit the OC.
-Please consider crediting the OC when reposting content. A name of the user or a link to the original post is sufficient.
...
...
Also check out:
Partnered Communities:
Reach out to LillianVS for inclusion on the sidebar.
All communities included on the sidebar are to be made in compliance with the instance rules.
view the rest of the comments
My 20 year old AC breaks once a year, at this point it's the ship of theseus. One year it's the capacitor on condensor, then condensor fan motor, then fan motor that circulates air instead, then circuit board that controls all HVAC functions, then capacitor for circulation fan. Every year, when the heat hits strong, something breaks, I have become proficient in diagnosting HVAC system at this point.
If you're going through multiple condensers a decade you need a new air conditioner. From a different manufacturer operating on a different continent.
We don't replace the whole thing, only the part that broke, and again, this system is 20+ years old
Yeah, at some point I would suggest replacing the unit as a whole rather than throwing parts at it constantly. For me, that point would come when the system can't survive a season.
A quick tip if you want to minimize the number of repairs. If a motor dies, replace all the start components as well. The old ones might be fully functional and even test good but when the motor quit it likely weakened them. Similarly, if one start component fails then just replace all of them for the same reason. A failing start cap or run cap can really beat up the start relay so even if it works temporarily, it will often fail later. Also if you notice that you keep having to replace start components for a particular motor then that motorcis starting to fail. We see that all the time with compressors in particular. A hard start kit can help in that case but it shouldn't be considered a fix.
The breakages happen a year apart when the summer heat gets bad, if we were going to replace a lot of components at once, at that point we could have just got a new system entirely as this one is really old